UK
Blind Bolt Company,
The Woodhouse,
Hopton Wafers,
Kidderminster,
Worcester,
DY14 0EE
Telephone: +44 (01299) 272 955
Fax: +44 (01299) 271 213
E-mail: enquiries@blindbolt.com
USA
Abrasive & Fastening Solutions Inc.
1217 S. Bridge St,
Yorkville,
IL 60560
Telephone: (630)882-9010
Fax: +44 (01299) 271 213
Australia
10 Mosrael Place,
Rowville,
Victoria.
3178.
Australia.
Telephone: +61 3 9757 4989
E-mail: sales@blindbolt.com.au
New Zealand
25 Victoria Street
Petone
Wellington
5070
Telephone: (04) 570 5000
E-mail: enquiries@blindbolt.com
Hong Kong
Wo Lee Green Solutions Limited.
G/F., 44 Bedford Road
TaiKokTsui
Kowloon
Telephone: +852 2393 0131
E-mail: enquiries@blindbolt.hk
Asia
AYS Ventures Berhad (925171-T)
Lot 6488,
Jalan Haji Abdul Manan,
42100 Klang,
Selangor Darul Ehsan,
Malaysia.
Telephone: +603-33775597
E-mail: enquiries@blindboltasia.com
NOTE: All dimensions are in mm unless stated otherwise.
The Blind Bolt Company reserve the right to change these technical details without notice.
Thin Wall Bolt Product Specification - Zinc Nickel |
||||
PRODUCT CODE |
HOLE DIAMETER |
DEPTH CLEARANCE |
CLAMPING RANGE |
|
(mm) | (mm) | MIN (mm) | MAX (mm) | |
TW5ZF-10 | 8 | 35 | 2 | 10 |
TW5ZF-16 | 8 | 40 | 8 | 16 |
TW6ZF-10 | 10 | 35 | 2 | 10 |
TW6ZF-16 | 10 | 40 | 8 | 16 |
TW8ZF-10 | 13 | 45 | 2 | 10 |
TW8ZF-16 | 13 | 50 | 8 | 16 |
Design Resistance for TW Type Blind Bolts |
![]() |
||||
TW Bolt Size |
Set Screw Diameter (mm) |
Collar Outside Diameter (mm) |
Hole Diameter (mm) |
Shear Resistance (kN) |
Tension Resistance (kN) |
TW5 | 5 | 7.8 | 8 | 13.2 | 4.8 |
TW6 | 6 | 9.5 | 10 | 19.5 | 14.1 |
TW8 | 8 | 12.6 | 13 | 34.5 | 25.6 |
Design resistances in shear and tension are presented above. The resistance values may be compared directly with the ultimate loads applied to the fixing.
The bearing resistance may be calculated in accordance with the design standard, based on the external diameter of the collar, as given above.
Fixings subject to combined shear and tension should be verified in accordance with the design standard, using the design resistances presented above.
If tension is applied to a fixing in a relatively thin wall application, the deformation of the connected material should be considered at serviceability (working loads) and at the ultimate limit state, as deformation is likely to be the limiting feature of the connection.
Design Resistance for TW Type Blind Bolts |
![]() |
||||
TW Bolt Size |
Set Screw Diameter (mm) |
Collar Outside Diameter (mm) |
Hole Diameter (mm) |
Shear Resistance (kN) |
Tension Resistance (kN) |
TW5 | 5 | 7.8 | 8 | 15.9 | 4.8 |
TW6 | 6 | 9.5 | 10 | 23.4 | 10.1 |
TW8 | 8 | 12.6 | 13 | 41.4 | 18.4 |
Design resistances in shear and tension are presented above. The resistance values may be compared directly with the ultimate loads applied to the fixing.
The bearing resistance may be calculated in accordance with the design standard, based on the external diameter of the collar, as given above.
Fixings subject to combined shear and tension should be verified in accordance with the design standard, using the design resistances presented above.
If tension is applied to a fixing in a relatively thin wall application, the deformation of the connected material should be considered at serviceability (working loads) and at the ultimate limit state, as deformation is likely to be the limiting feature of the connection.
Thin Wall Bolt Product Specification |
||||
PRODUCT CODE |
HOLE DIAMETER |
DEPTH CLEARANCE |
CLAMPING RANGE |
|
(mm) | (mm) | MIN (mm) | MAX (mm) | |
TW5SS-10 | 8 | 35 | 2 | 10 |
TW5SS-16 | 8 | 40 | 8 | 16 |
TW6SS-10 | 10 | 35 | 2 | 10 |
TW6SS-16 | 10 | 40 | 8 | 16 |
TW8SS-10 | 13 | 45 | 2 | 10 |
TW8SS-16 | 13 | 50 | 8 | 16 |
Design Resistance for TW Type Blind Bolts |
![]() |
||||
TW Bolt Size |
Set Screw Diameter (mm) |
Collar Outside Diameter (mm) |
Hole Diameter (mm) |
Shear Resistance (kN) |
Tension Resistance (kN) |
TW5 | 5 | 7.8 | 8 | 11.6 | 7.0 |
TW6 | 6 | 9.5 | 10 | 17.3 | 9.8 |
TW8 | 8 | 12.6 | 13 | 30.4 | 17.9 |
Design resistances in shear and tension are presented above. The resistance values may be compared directly with the ultimate loads applied to the fixing.
The bearing resistance may be calculated in accordance with the design standard, based on the external diameter of the collar, as given above.
Fixings subject to combined shear and tension should be verified in accordance with the design standard, using the design resistances presented above.
If tension is applied to a fixing in a relatively thin wall application, the deformation of the connected material should be considered at serviceability (working loads) and at the ultimate limit state, as deformation is likely to be the limiting feature of the connection.
Design Resistance for TW Type Blind Bolts |
![]() |
||||
TW Bolt Size |
Set Screw Diameter (mm) |
Collar Outside Diameter (mm) |
Hole Diameter (mm) |
Shear Resistance (kN) |
Tension Resistance (kN) |
TW5 | 5 | 7.8 | 8 | 14.0 | 5.0 |
TW6 | 6 | 9.5 | 10 | 20.8 | 7.1 |
TW8 | 8 | 12.6 | 13 | 36.4 | 12.9 |
Design resistances in shear and tension are presented above. The resistance values may be compared directly with the ultimate loads applied to the fixing.
The bearing resistance may be calculated in accordance with the design standard, based on the external diameter of the collar, as given above.
Fixings subject to combined shear and tension should be verified in accordance with the design standard, using the design resistances presented above.
If tension is applied to a fixing in a relatively thin wall application, the deformation of the connected material should be considered at serviceability (working loads) and at the ultimate limit state, as deformation is likely to be the limiting feature of the connection.